,Heating Capacity##HVAC_HEATING_LOAD##BRITISH_THERMAL_UNITS_PER_HOUR,Width##LENGTH##INCHES,Length##LENGTH##INCHES,Height##LENGTH##INCHES,Media Cabinet##OTHER##,Media Cabinet Height##LENGTH##INCHES,Model##OTHER##,Voltage##ELECTRICAL_POTENTIAL##VOLTS,Full Load Current##ELECTRICAL_CURRENT##AMPERES,Maximum Overcurrent Protection##ELECTRICAL_CURRENT##AMPERES,Power Factor##OTHER##,Number of Poles##OTHER##,Supply Air Width##HVAC_DUCT_SIZE##INCHES,Supply Air Height##HVAC_DUCT_SIZE##INCHES,Top Vent Upflow X Offset##LENGTH##INCHES,Return Air Width##HVAC_DUCT_SIZE##INCHES,Cabinet Return Air Width##HVAC_DUCT_SIZE##INCHES,Return Air Height##HVAC_DUCT_SIZE##INCHES,Gas Diameter##PIPE_SIZE##INCHES,Vent Diameter##PIPE_SIZE##INCHES,Type Comments##OTHER##,Shipping Weight##MASS##POUNDS_MASS,Description##OTHER##,Manufacturer##OTHER##,URL##OTHER##
"800SM045M1412 - 14"" Width",45000,29,14.1875,33.33333333,0,16,800SM045M1412,115,4.4,15,0.9,1,13,19,9.3125,13,13,22,0.5,4,"45 kBtu Heating Capacity. 14"" Cabinet Width",108,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM045M1714 - 17"" Width",45000,29,17.5,33.33333333,0,16,800SM045M1714,115,6.7,15,0.9,1,16,19,11.5625,16,16,22,0.5,4,"45 kBtu Heating Capacity. 17"" Cabinet Width",121,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM070M1412 - 14"" Width",70000,29,14.1875,33.33333333,0,16,800SM070M1412,115,4.4,15,0.9,1,13,19,9.3125,13,13,22,0.5,4,"70 kBtu Heating Capacity. 14"" Cabinet Width",114,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM070M1712 - 17"" Width",70000,29,17.5,33.33333333,0,16,800SM070M1712,115,4.4,15,0.9,1,16,19,11.5625,16,16,22,0.5,4,"70 kBtu Heating Capacity. 17"" Cabinet Width",124,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM070M1716 - 17"" Width",70000,29,17.5,33.33333333,0,16,800SM070M1716,115,8.8,15,0.9,1,16,19,11.5625,16,16,22,0.5,4,"70 kBtu Heating Capacity. 17"" Cabinet Width",127,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM070M2116 - 21"" Width",70000,29,21,33.33333333,0,20,800SM070M2116,115,8.8,20,0.9,1,20,19,13.3125,20,20,22,0.5,4,"70 kBtu Heating Capacity. 21"" Cabinet Width",139.5,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM090M1714 - 17"" Width",90000,29,17.5,33.33333333,0,16,800SM090M1714,115,6.7,15,0.9,1,16,19,11.5625,16,16,22,0.5,4,"90 kBtu Heating Capacity. 17"" Cabinet Width",133,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM090M2116 - 21"" Width",90000,29,21,33.33333333,0,20,800SM090M2116,115,6.7,20,0.9,1,20,19,13.3125,20,20,22,0.5,4,"90 kBtu Heating Capacity. 21"" Cabinet Width",140.5,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM090M2120 - 21"" Width",90000,29,21,33.33333333,0,20,800SM090M2120,115,11.5,20,0.9,1,20,19,13.3125,20,20,22,0.5,4,"90 kBtu Heating Capacity. 21"" Cabinet Width",147,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM090M2420 - 24"" Width",90000,29,24.5,33.33333333,0,24,800SM090M2420,115,8.8,20,0.9,1,24,19,13.3125,24,24,22,0.5,4,"90 kBtu Heating Capacity. 24"" Cabinet Width",147,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM110M2120 - 21"" Width",110000,29,21,33.33333333,0,20,800SM110M2120,115,11.5,20,0.9,1,20,19,13.3125,20,20,22,0.5,4,"110 kBtu Heating Capacity. 21"" Cabinet Width",150,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM110M2420 - 24"" Width",110000,29,24.5,33.33333333,0,24,800SM110M2420,115,8.8,20,0.9,1,24,19,15.0625,24,24,22,0.5,4,"110 kBtu Heating Capacity. 24"" Cabinet Width",165,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM135M2420 - 24"" Width",135000,29,24.5,33.33333333,0,24,800SM135M2420,115,8.8,20,0.9,1,24,19,15.0625,24,24,22,0.5,4,"135 kBtu Heating Capacity. 24"" Cabinet Width",167,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM155M2420 - 24"" Width",155000,29,24.5,33.33333333,0,24,800SM155M2420,115,8.8,20,0.9,1,24,19,15.0625,24,24,22,0.5,4,"155 kBtu Heating Capacity. 24"" Cabinet Width",171,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM045M1412 - 14"" Width - 16"" Media Filter Cabinet",45000,29,14.1875,33.33333333,1,16,800SM045M1412,115,4.4,15,0.9,1,13,19,9.3125,13,13,22,0.5,4,"45 kBtu Heating Capacity. 14"" Cabinet Width with 16"" Media Filter Cabinet",108,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM045M1714 - 17"" Width - 16"" Media Filter Cabinet",45000,29,17.5,33.33333333,1,16,800SM045M1714,115,6.7,15,0.9,1,16,19,11.5625,16,16,22,0.5,4,"45 kBtu Heating Capacity. 17"" Cabinet Width with 16"" Media Filter Cabinet",121,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM070M1412 - 14"" Width - 16"" Media Filter Cabinet",70000,29,14.1875,33.33333333,1,16,800SM070M1412,115,4.4,15,0.9,1,13,19,9.3125,13,13,22,0.5,4,"70 kBtu Heating Capacity. 14"" Cabinet Width with 16"" Media Filter Cabinet",114,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM070M1712 - 17"" Width - 16"" Media Filter Cabinet",70000,29,17.5,33.33333333,1,16,800SM070M1712,115,4.4,15,0.9,1,16,19,11.5625,16,16,22,0.5,4,"70 kBtu Heating Capacity. 17"" Cabinet Width with 16"" Media Filter Cabinet",124,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM070M1716 - 17"" Width - 16"" Media Filter Cabinet",70000,29,17.5,33.33333333,1,16,800SM070M1716,115,8.8,15,0.9,1,16,19,11.5625,16,16,22,0.5,4,"70 kBtu Heating Capacity. 17"" Cabinet Width with 16"" Media Filter Cabinet",127,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM070M2116 - 21"" Width - 20"" Media Filter Cabinet",70000,29,21,33.33333333,1,20,800SM070M2116,115,8.8,20,0.9,1,20,19,13.3125,20,20,22,0.5,4,"70 kBtu Heating Capacity. 21"" Cabinet Width with 20"" Media Filter Cabinet",139.5,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM090M1714 - 17"" Width - 16"" Media Filter Cabinet",90000,29,17.5,33.33333333,1,16,800SM090M1714,115,6.7,15,0.9,1,16,19,11.5625,16,16,22,0.5,4,"90 kBtu Heating Capacity. 17"" Cabinet Width with 16"" Media Filter Cabinet",133,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM090M2116 - 21"" Width - 20"" Media Filter Cabinet",90000,29,21,33.33333333,1,20,800SM090M2116,115,6.7,20,0.9,1,20,19,13.3125,20,20,22,0.5,4,"90 kBtu Heating Capacity. 21"" Cabinet Width with 20"" Media Filter Cabinet",140.5,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM090M2120 - 21"" Width - 20"" Media Filter Cabinet",90000,29,21,33.33333333,1,20,800SM090M2120,115,11.5,20,0.9,1,20,19,13.3125,20,20,22,0.5,4,"90 kBtu Heating Capacity. 21"" Cabinet Width with 20"" Media Filter Cabinet",147,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM090M2420 - 24"" Width - 24"" Media Filter Cabinet",90000,29,24.5,33.33333333,1,24,800SM090M2420,115,8.8,20,0.9,1,24,19,13.3125,24,24,22,0.5,4,"90 kBtu Heating Capacity. 24"" Cabinet Width with 24"" Media Filter Cabinet",147,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM110M2120 - 21"" Width - 20"" Media Filter Cabinet",110000,29,21,33.33333333,1,20,800SM110M2120,115,11.5,20,0.9,1,20,19,13.3125,20,20,22,0.5,4,"110 kBtu Heating Capacity. 21"" Cabinet Width with 20"" Media Filter Cabinet",150,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM110M2420 - 24"" Width - 24"" Media Filter Cabinet",110000,29,24.5,33.33333333,1,24,800SM110M2420,115,8.8,20,0.9,1,24,19,15.0625,24,24,22,0.5,4,"110 kBtu Heating Capacity. 24"" Cabinet Width with 24"" Media Filter Cabinet",165,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM135M2420 - 24"" Width - 24"" Media Filter Cabinet",135000,29,24.5,33.33333333,1,24,800SM135M2420,115,8.8,20,0.9,1,24,19,15.0625,24,24,22,0.5,4,"135 kBtu Heating Capacity. 24"" Cabinet Width with 24"" Media Filter Cabinet",167,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com
"800SM155M2420 - 24"" Width - 24"" Media Filter Cabinet",155000,29,24.5,33.33333333,1,24,800SM155M2420,115,8.8,20,0.9,1,24,19,15.0625,24,24,22,0.5,4,"155 kBtu Heating Capacity. 24"" Cabinet Width with 24"" Media Filter Cabinet",171,"Base 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces",Bryant,www.bryant.com